6290W Touchscreen Home Security System
Full Installation Guide [Part Number 800-24918] available online at: https://mywebtech.honeywellhome.com
To reset the Touchscreen, press and hold the side Power Button for 3 seconds and then select the reset button
can also be reset by pressing and holding the reset button for approximately 15 seconds until the touchscreen resets automatically.
TOUCHSCREEN INITIALIZATION
When initially powered, the boot sequence and the "Set ECP Address" is displayed. If
using one Touchscreen, leave the address set to 1 and select Apply. If using more
than one, power-up each Touchscreen one at a time, and set each Touchscreen
address to one of the addresses enabled in the control panel.
Operation Mode Selection: Select Normal Mode, Safe Mode or Demo Mode to turn
the option on or off.
SYSTEM INFORMATION / UPGRADES
To view the current software version installed, Interface name and MAC Address,
select Setup
→ System Information.
Software upgrades may be available. Log in to MyWebTech (see above) and enter
the model name in the "Search by" "My Product" field. Select Go; click on
Touchscreen software update SBS".
ECP ADDRESS
If the screen is displaying "ECP Error", the ECP address in the Touchscreen is not
valid for the panel that it is connected to. In this case, to change the ECP Address,
enter the default code of "4140" to advance to the next screen.
Note: Default code "4140" is the Touchscreen default installer code before connecting
to a control panel. Once connected to a control panel, use that panel's installer code.
1. Select Setup
→System Setup
2. Enter an Authorized Code, if required.
3. Select ECP Address&Options
Addresses are:
1-2, 5-6.... for residential controls
1-2, 3-30... for commercial controls under Rev. 10; supports 3 AUIs. *See
Important Note below.
1-30 ....... for commercial controls Rev. 10 or higher; supports 6 AUIs.
*IMPORTANT NOTE: If multiple Touchscreens are being used, they must be set to
addresses 1, 2, and X (where X equals any address from 3 through 30). Only one
AUI type (Touchscreen) device may be assigned to an address from 3 through 30 on
commercial control panels.
4. Select the Homepage and Operation Mode from the Options menu.
DISPLAY & AUDIO SETUP
1. From the Home/Security screen select Setup
bar up or down to change settings.
2. Select Setup → Disp & Audio Setup
- To adjust the screen timeouts, select a time interval from the drop-down list for
each option (Backlight Off After, To Homepage After, and Auto Slideshow After.)
- Select Chime, Voice or Voice Chime operating mode.
- To clean the Touchscreen screen, select the Clean Screen icon; select
Continue, or select Cancel to exit.
- Changes are saved when you exit
USER SETUP
1. Select Setup → System Setup → USER
2. Select
and enter a User name and enter an Authorized Code for this user.
Select each field and enter the appropriate information.
3. Select
to save the user information or select Back
previous screen.
For available user numbers, see control panel instructions.
TIME & DATE
1. Select Setup
→ System Setup→ Time/Date Setup
2. Enter an "Authorized Code".
a) If Get Time is selected, the Touchscreen downloads the time/date from the
control panel and exits the "Set Time" screen. (The Get Time icon appears with
residential panels and may not appear with all commercial panels.)
b) Or, set the time/date from the Set Time/Date screen.
to save: A pop-up message displays "Time Setting Confirmation",
3. Select
select Yes or No.
Panel Faults – If
Panel Fault icons are displayed on the Security screen, contact your alarm company. See the full Installation Guide.
Expander Failure
AC Loss
Bell Failure
Quick Installation Guide
→ CS Setup
.
; enter an ECP Address. The available ECP
, slide the Brightness / Volume
; enter an Authorized Code.
this screen.
.
arrow to return to the
.
Low Battery
LRR Supervision Failure
on the screen to start the reset function. The Touchscreen
MULTIMEDIA
NOTE: Micro SD card max size is 64GB and must be FAT32, SDXC format. Recommended is
Kingston or Samsung.
Picture Setup: Insert a media card (Micro SD/SDHC) with up to 1000 stored (jpg,
.bmp, .png or .jpeg) photos.
1. Select the Multimedia
2. Select a photo and select Play
3. To set a picture as wallpaper, select the Default/Wallpaper folder to activate the
wallpaper setting.
4. Select the Multimedia information
5. Select Back
to return to the previous screen.
Video Setup: Insert a media card (Micro SD/SDHC) with stored (avi, .ts, .mpg, .mp4,
.mov, .mkv, or .flv) video files.
1. Select the Multimedia
2. Select Play
to start the selected video file.
3. Select the Multimedia information
4. Select Back
to return to the previous screen.
SCREEN SECURITY
See the full Installation Guide for user Authority Levels.
1. Select Setup → System Setup → CS Setup
2. Enter an Authorized Code; select Screen Security
- To make changes, select the line to change and the level of user to have
access, and then slelct
CODE AUTHORITY
1. Select Setup → System Setup → CS Setup.
2. Select Code Authority
3. Enter the 4-digit Code for the user you want to obtain authority level information
about.
PANEL CONFIGURATION
1. Select Setup → System Setup → CS Setup.
2. Enter an Authorized Code and select Panel Config
Select
to clear the Touchscreen and reload the panel configuration into the
Touchscreen.
NIGHT SETUP
The NIGHT function can be set to arm the system in one of five arming modes. To
change the arming mode;
1. Select Setup →System Setup → Advanced Setup.
2. Enter an Authorized Code.
3. Select Night Setup; select desired mode:
Away - Stay - Instant (default) - Night (Residential Panel Only) – Maximum.
4. Select
to save changes.
EMERGENCY MESSAGES
1. Select the PANIC Icon.
2. Select and hold (for at least 2 seconds) the associated alarm icon (FIRE, POLICE
or MEDICAL).
DISARMING THE SYSTEM AND SILENCING ALARMS
To silence Alarms or Trouble conditions: enter your 4-digit user code, select the
Clear button, then enter your 4-digit user code again.
To test the Alarm, select the Security
- Select Console Mode
procedure.
Use a UL Listed, battery-backed supply for UL installations. The battery supplies
power to these keypads in case of AC power loss. The battery-backed power supply
should have enough power to supply the keypads with the UL required minimum
U L
standby power time.
IMPORTANT: Touchscreens powered from supplies that do not have a backup
battery do not function if AC power is lost. Make sure to power at least one keypad
in each partition from the control's auxiliary power output or UL Listed battery backed
up power supply.
Max Attempts
Pager Failure
Exceeded
icon and then select the Picture folder to view.
to view pictures in a slide show format.
icon to view picture/video information.
icon and then select the Video folder to view.
icon to view picture/video information.
.
.
to save changes.
.
.
and More Choices
and refer to the Control Panel User Guide for
Wireless Failure
Telco-2 Cut
Telco-1 Cut
icons.
Panic